Architectural Library
Our mission at Bristolite is to provide our customers with the highest quality products and supreme service at an exceptional value. We also aim to provide the industry with an abundance of accurate and useful information relative to daylighting and energy conservation. We take our corporate responsibility to our employees, associates, industry colleagues and customers very seriously and we see ourselves as stewards for the efficient use of sustainable carbon free energy.

ASTM D1735-08

Testing Water Resistance of Coatings Using Water Fog Apparatus

This standard practice covers the basic principles and operating procedures for testing water resistance of coatings using water fog apparatus.

The test specimen shall be the sample of a final manufactured product of which quantity, size, material and finish shall be agreed upon prior to testing. The specimen shall be coated as per manufacturer’s instructions. There shall be a sample product with a known paint durability to compare data along with at least two replicate specimens of each different coating.

During the test a reservoir is filled with water that has been prepared by distillation, continuous electrodeionization, ion exchange, reverse osmosis or a combination thereof as per Type IV on D1193 - Table 1. The water shall be heated and maintained for the duration of the test, whilst being circulated, to between 36°C - 40°C (96°F - 104°F), if not specified otherwise prior to testing. The specimen shall be submersed and supported in the testing unit at an angle of 15°. If multiple specimens are being tested then all shall be freely exposed to the fogging and free from affecting each other with a recommended minimum spacing of 30mm (1-3/16”). The fog is to be collected from the nozzle by two containers within the testing unit. One shall be close, within 10cm (4”) of the fogging nozzle and the other shall be as far away as possible. The collection rates are recorded in mL/h and are measured every 24hrs. After the specimen has been tested within several different section of the testing unit and the atomizing air supply has been adjusted to allow for about 2.0mL of water/hr to be collected then remove the specimen after a previously allotted timescale then wipe dry and rate changes, if any. If possible, ratings should also take place after the moisture has dried out of the specimen(s).

    Leed Credits Estimate

    Please complete the information requested below including the Bristolite model number you plan to specify and/or purchase.

  • Name:
  • Company:
  • Telephone :
  • Email:
  • Project Name :
  • Bristolite Model Number:
  •  
  • You will receive by return email a LEED Credits Worksheet providing an estimate for the following.

    Post Industrial / Pre-Consumer Recycled Content ______%
    Material used in manufacturing of the product.

    Post Consumer Recyclable Content ______%
    Recyclable material after product life.

    Local Regional Materials _____% (Our materials do not routinely qualify)
    Material Inbound/Outbound sourced within 500 miles of destination.

Trituff Copolyester Passes 267 lb/
36" ASTM Drop Test

A new, pending ASTM skylight fall protection drop test requires dropping a 267 lb sand filled canvas bag with a 5.5" bull nose from a height of 36" on the skylight glazing. As evidenced by this video Trituff Coployester passes the test. The total impact force and pressure developed in this test is 2,278.6 foot pounds and 95.9 lb per square inch.

Tufflite Heavy Weather / High Security Polycarbonate Takes a Tromping

Rick Beets, Bristolite President, demonstrates the resilience of Tufflite for customers. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate Takes a Beating

Rick Beets, Bristolite President, demonstrates the impact resistance of Tufflite for customers. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA# 10-0216.02 and Florida Building Code Approved # FL14006.

Energy Star Fiberlite CC1 Fire Resistance

Energy Star Fiberlite, Trituff Copolyester and Tufflite Polycarbonate are all CC1 Fire Rated.

Custom Glass Skylight Positive Load Cycling after Large Missile Impact Test

Positive load cycling from 10.30 psf to 51.38 psf after large missile impact test. This model 1000 custom glass skylight series is Miami Dade County Hurricane Zone Approved NOA # 07-0524.05.

Custom Glass Skylight Positive and Negative Load Cycling

Positive load cycling from 10.30 psf to 51.38 psf and negative load cycling from 20.6 psf to 34.3 psf. This model 1000 custom glass skylight series is Miami Dade County Hurricane Zone Approved NOA # 07-0524.05.

Custom Glass Skylight Negative Load Cycling

Negative load cycling from 20.6 psf to 34.3 psf after multiple large missile impact tests. This model 1000 custom glass skylight series is Miami Dade County Hurricane Zone Approved NOA # 07-0524.05.

Custom Glass Skylight Large Missile Impact Test

Large missile impact test requires firing a 9 lb missile at a velocity of 49 fps to 50 fps at a distance of 17 ft from the skylight. This model 1000 custom glass skylight series is Miami Dade County Hurricane Zone Approved NOA # 07-0524.05.

Custom Glass Skylight Large Missile Impact Test

Large missile impact test requires firing a 9 lb missile at a velocity of 49 fps to 50 fps at a distance of 17 ft from the skylight. This model 1000 custom glass skylight series is Miami Dade County Hurricane Zone Approved NOA # 07-0524.05.

20 Year Old Energy Star Fiberlite
Supports 5,000 lb

20 year old Energy Star Fiberlite supports 5,000 lb in a concentrated (1 sq ft) load test by an independent 3rd party testing laboratory.

Trituff Copolyester Supports 1,950 lb

Trituff Copolyester supports 1,950 lb in a concentrated (1 sq ft) load test by an independent 3rd party testing laboratory.

Tufflite Heavy Weather / High Security Polycarbonate Negative Load Cycling

Negative 19.5 psf to 32.5 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate Positive Load Cycling

Positive 11.0 psf to 55.0 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate Negative Load Cycling

Negative 19.5 psf to 32.5 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security
Positive and Negative Load Cycling

Positive 11.0 psf to 55.0 psf and negative 19.5 psf to 32.5 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate Negative Load Cycling

Negative 19.5 psf to 32.5 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate
Positive and Negative Load Cycling

Positive 11.0 psf to 55.0 psf and negative 19.5 psf to 32.5 psf load cycling. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Gladiator Safety Screen
Supports 600 lb Static Load

Gladiator Safety Screen installed on a wood curb supports two 300 lb loads in opposing corners.

Gladiator Safety Screen
Supports 867 lb Static Load

Gladiator Safety Screen installed on a wood curb supports two 300 lb loads in opposing corners and a 267 lb load in the center for a total static load of 867 lb

Gladiator Safety Screen
Passes 267 lb / 36" ASTM Drop Test

A new, pending ASTM skylight fall protection drop test requires dropping a 267 lb sand filled canvas bag with a 5.5" bull nose from a height of 36" on the skylight glazing. As evidenced by this video our Gladiator Safety Screen passes the test. The total impact force and pressure developed in this test is 2,278.6 foot pounds and 95.9 lb per square inch.

Gladiator Safety Screen
Passes 267 lb / 36" ASTM Drop Test

A new, pending ASTM skylight fall protection drop test requires dropping a 267 lb sand filled canvas bag with a 5.5" bull nose from a height of 36" on the skylight glazing. As evidenced by this video our Gladiator Safety Screen passes the test. The total impact force and pressure developed in this test is 2,278.6 foot pounds and 95.9 lb per square inch.

Tufflite Heavy Weather / High Security Polycarbonate Large Missile Impact Test

Large missile impact test requires firing a 9 lb missile at a velocity of 49 fps to 50 fps at a distance of 17 ft from the skylight. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.

Tufflite Heavy Weather / High Security Polycarbonate Large Missile Impact Test

Large missile impact test requires firing a 9 lb missile at a velocity of 49 fps to 50 fps at a distance of 17 ft from the skylight. This Tufflite model HWHS (Heavy Weather High Security) skylight is Miami Dade County Hurricane Zone Approved NOA # 10-0216.02 and Florida Building Code Approved # FL14006.